Temperature sensor |
4 wire PT100 1/3 DIN (DIN EN 60751 |
Long-term stability |
±0.5 °C/year |
Measuring range |
-200...200°C* (*see data sheet) |
Relative humidity range |
0…100 %rh |
Digital output signal (standard) |
UART |
Storage Conditions |
-40…85 °C |
IP protection rating |
Housing: IP65 Sensor : IP68 |
Connector |
Standard Rotronic 7-pin connector |
Length |
110 mm |
Communication interfaces |
MODBUS RTU |
Probe material |
Stainless steel - austenitic - 1.4571 (316Ti) bar |
Probe cable material |
Perfluoroalkoxy alkanes (PFA) |
Enclosure material |
Polycarbonate |
Probe lengths |
50 mm |
Housing |
Yes |
Current consumption |
-3.8 mA |
Power supply |
3.3…5 VDC |
Adjustment |
Option 1: 2 point user adjustment possible Option 2: A, B and C coefficients |
Evaluation software / Compatibility |
RMS Config; Rotronic Monitoring System |
T63 |
90 s |
Battery lifetime |
RMS-LOG-868/915/L: @60 s 240 d RMS-LOG-L-D: @60s 18 d |
Cable lengths |
2 metres |
Accuracy |
±0.25 °C at -50…85 °C |
Diameter |
15 mm |
Cable diameter |
2.2 mm |
Probe diameter |
3 mm |